Seimi Marine Equipment

Oil marine stoves
REFLEKS oil marine stoves are made of first class stainless steel and are tested under maritime conditions. They are easy to install and give you the best safety on board (equipped with cc oil control). They burn with a constant flame. Choose your module.

 Serie 66 - For boats up to 13 m long (24 m3).


 

66 M

66 MF

66 MK

66 MKS
Comfort on Board, click to dowload the brochure
Click to download
the brochure
PDF document (990 Ko)

 Serie 62 - For boats up to 15 m long (32 m3).


 

62 M

 Serie 60 M - For boats up to 20 m long (70 m3).


 

60 M

61 MS


Type 66M 66MW 66MK 66MV 62M 62MS 64M 60M 61MS 67MS 67MV 71M 71MS 70M
Capacity,kcal. air heating 1400 1400 1400   2100 700 5000 5000 1600 2000   1400 1000 1400
Capacity,kcal. radiator heating       1400   1400     3400 4200 7000   400  
Height, mm 420 370 450 550 440 440 630 620 715 900 760 250 250 345
Diameter,mm=20 165   165 240 260 260 320 320 320 365        
Width, mm   170                 400 250 250 325
Depth, mm   280                 400 250 250 495
Ventilation, mm 70 70 70 70 90 90 90 90 90 114 114 70 70 70
Ventilation from floor, mm 420 370 345 490 345 345 525 420 525 760 715 205 205 345
Fresh air intake, mm 70 70 70 70 90 90 90 90 90 114 114 70 70  
Weight in kgs 4 6 4.5 8 7 8 10 10 14 18 30 8.5 9 18
Consumption,min. Litre/hour 0.12 0.12 0.12 0.12 0.12 0.12 0.18 0.18 0.18 0.3 0.3 0.12 0.12 0.12
Consumption, max. Litre/hour 0.3 0.3 0.3 0.36 0.36 0.36 0.8 0.8 0.8 1.0 1.5 0.3 0.3 0.36
Heat max m3 without insulation 14 14 14 14 21 21 50 50 50 62 70 14 14 14
Heat max m3 with insulation 23 23 23 23 35 35 83 83 83 103 117 23 23 23

Contribution/comparison 1,2 KW - 1.030 Kcal/h
  • M = Model
  • K = Cooking plate
  • S = Heating coil connections for central heating unit
  • F = Air intake
  • V = Stainless steel boiler for connecting to central heating unit
  • W = Fitted with bulkhead fittings and built in regulator
  • C = Air intake duct
1 Kcal = 3.97 BTU
1 BTU = 0.25 Kcal

The heating capacity of an oil stove is calculated with an outside temperature of -20 degrees centigrade.
The heat required for a particular ship is calculated on a basis of the following:
  • A noninsulated ship requires: 100 kcal. per m3
  • An insulated ship requires : 60 kcal. per m3
All oil stoves with the letters MF as part of the model number (e.g. 66MF), have a right angled (90 degrees) duct for fitting to the air intake, included in the price.
Model 66MF is also fitted with bulkhead fittings.
Models 66MK, 71M, 71MS and 70M are made only with cast iron cooking plates.

The following stove types can be delivered with cast iron cooking platesif specially ordered: 62M, 62MS, 64M, 60M, 61MS and 67MS.
All stoves with cast iron cooking plates are fitted with a fiddle rail.


Installation: